Chapter 20 Switcher Setup (Switcher)
1249
Interfacing With External Devices (Device Interface Menu)
Test firing the trigger
To test fire the trigger, press [Test Fire].
This outputs a trigger from the selected output port. This is not output when the
trigger type is “Status.”
Enabling or Disabling AUX Bus Control
1
In the Switcher >Device Interface menu, press [Aux Control].
The Aux Control menu appears.
2
Select the 9-pin port for the setting, from the <Control> group.
Remote1: Make the settings for the REMOTE1 port.
Remote2: Make the settings for the REMOTE2 port.
Remote3: Make the settings for the REMOTE3 port.
Remote4: Make the settings for the REMOTE4 port.
3
Using any of the following methods, select the AUX bus.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
a) 0: EDIT PVW
1 to 48: AUX1 to AUX48
4
Select whether to enable or disable AUX bus control from the <Control
Mode> group.
Enable: enable control of the port selected in step 2.
Disable: disable control of the port selected in step 2.
Manual: make whether control of the port selected in step 2 is possible or
not depend on the setting in the Misc menu.
5
Repeat steps 2 to 4 as required to make the settings for other ports.
Setting the Interface Between the DME and the Switcher
To set the interface between the DME and the switcher when the DME is an
MVE-8000A or MVE-9000, proceed as follows.
Knob Parameter Adjustment Setting values
1 No AUX bus selection
0 to 48
a)