Chapter 21 DME Setup (DME)
1260
Interfacing With External Devices (Device Interface Menu)
Making DME GPI Input Settings
1
In the DME >Device Interface menu, press [DME1 GPI Input].
The DME1 GPI Input menu appears.
2
Using any of the following methods, select the settings.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knobs.
3
In the <Trigger Type> group, select the trigger polarity.
(Rising Edge): Apply the trigger on a rising edge of an input pulse.
(Falling Edge): Apply the trigger on a falling edge of an input
pulse.
(Any Edge): Apply the trigger on a change in the polarity of the
input signal.
(Level): Carry out the specified operation when the input is low or
high.
No Operation: Apply no trigger on an input pulse.
4
In the <Target> group, select what this applies to (channels 1 to 4, or Proc).
5
Using any of the following methods, select the action to be set.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knobs.
a) As for the setting values, see “Selectable actions for various trigger types” (page 1261).
b) When knob 3 selection is “Snapshot”
c) When knob 3 selection is “Effect”
6
Press [Action Set] to confirm the action selection.
Knob Parameter Adjustment Setting values
1 Port Input port selection 1 to 8
2 No Selection of number for action to
be assigned
1 to 8
Knob Parameter Adjustment Setting values
3 Action Action selection
1 and upwards
a)
4 Reg No Register number
1 to 99
b)
1 to 399
c)