Chapter 19 Control Panel Setup (Panel)
1157
Cross-Point Settings (Xpt Assign Menu)
2
Using any of the following methods, select the table.
• Press directly on the list on the right of the status area.
• Press the arrow keys on the list on the right to scroll the reverse video
cursor.
• Turn the knob.
3
Press [Table Assign Set].
This sets the table for the selected switcher bank or bus.
Exporting Source Names and Destination Names
To send the source names and destination names to the S-Bus, use the
following procedure.
1
In the Panel >XPT Assign menu, press [Name Export].
The Name Export menu appears.
2
Turn the knob to set the station ID.
a) If set to 255, the information is sent to all stations (with display of “All”).
3
Press [Src Name Export].
This exports the source names to the station selected in step 2.
4
Press [Dest Name Export].
This exports the destination names to the station selected in step 2.
Notes
Since destination names cannot be selected freely, fixed names are used.
Knob Parameter Adjustment Values
3 Table No Selection of table
to be assigned
1 to 15
Knob Parameter Adjustment Setting values
1 Station ID Station ID setting
1 to 255
a)