Chapter 6 DME Wipes
349
Basic Procedure for DME Wipe Settings
c) The vertical center position of the video pasted on Side V. At –100.00 the center is at the bottom
edge of the screen, and at +100.00 the center is at the top edge of the screen.
a) Shared with knob 3 for parameter group 1
b) The horizontal center position of the video pasted on Side H. At –100.00 the center is at the left
edge of the screen, and at +100.00 the center is at the right edge of the screen.
c) The vertical center position of the video pasted on Side H. At –100.00 the center is at the bottom
edge of the screen, and at +100.00 the center is at the top edge of the screen.
Setting DME Wipe Modifiers
You can apply various modifiers to the DME wipe pattern: setting the DME
wipe direction, pattern position, and so on.
For an overview of the DME wipe modifiers, see “DME Wipe Pattern
Variation and Modifiers” (page 342).
Specifying the DME wipe direction (Direction)
You can specify the DME wipe direction (normal/reverse).
To specify the DME wipe direction in a menu
1
In the M/E-1 >DME Wipe menu, select HF4 ‘Edge/Direction.’
The Edge/Direction menu appears.
2
In the <Direction> group, specify the DME wipe direction.
Normal: regular direction
Normal/Reverse: alternate between regular and reverse for each transition
Reverse: reverse direction to normal
Parameter group [2/2]
Knob Parameter Adjustment Setting values
1 Side H Size X Side H horizontal
magnification
0.01 to 8.00
2 Side H Size Y Side H vertical
magnification
0.01 to 8.00
3 Height Height of brick
0.01 to 100.00
a)
4 Side H Center X Side H horizontal center
position
–100.00 to +100.00
b)
5 Side H Center Y Side H vertical center
position
–100.00 to +100.00
c)