Chapter 19 Control Panel Setup (Panel)
1196
Operation Settings (Operation Menu)
4
When making a macro attachment setting, select whether or not to enable
cross-point button operations in the <Attachment Setting Mode> group.
With Btn Function: enable cross-point button operations
W/o Btn Function: disable cross-point button operations
5
Using the <Macro 2nd Recall Mode> group, set the action to occur during
macro execution or when a macro is stopped, if the cross-point button with
the macro attachment set is pressed again.
Continue: Execution of a macro that has been stopped is resumed, and an
executing macro continues.
Cancel: A stopped macro, or a macro during execution is terminated.
6
Using the <Macro Recall Override> group buttons, set the action to occur
during macro execution or when a macro is stopped, if another macro is
recalled.
Disable: Ignore the other macro recall.
Enable: Execute the other macro.
To have a cross-point button with a macro attachment set lit
continuously
Press [Attchd Btn Indication], turning it on.
When the [MCRO ATTCH ENBL] button in the cross-point control block is
on, the cross-point button with a macro attachment is constantly lit green.