Chapter 16 Macros
953
Macro Operations in the Standard Type Flexi Pad Control Block
If the same register is recalled again during macro execution or when the
macro is paused, the following operation depends on a setting in setup.
For details of the settings, see “Setting the Macro Execution Mode” in
Chapter 19 (Volume 3).
Individual events stored in a macro are executed according to the
settings in setup. If you change the settings in setup, a saved macro may
not have the expected effect.
During macro execution, if you switch the control panel to macro editing
mode, the macro being executed stops.
During macro editing it is not possible to execute a macro.
While executing a macro with the numeric keypad control block,
Multifunction Flexi Pad control block, Flexi Pad control block for
another switcher bank, or with a button with a macro attachment set, if
you recall another macro with the Flexi Pad control block, the following
operation depends on a setting in setup.
For details of the settings, see “Setting the Macro Execution Mode” in
Chapter 19 (Volume 3).
Executing a macro in normal execution mode (with pause events
set)
When execution of a macro is paused, the [Take] button is assigned to the
memory recall section.
To restart the macro execution, press the [Take] button.
You can switch the normal execution mode and step execution mode in the
Setup menu. See “Setting the Macro Execution Mode” in Chapter 19 (Volume
3).
Executing a macro in step execution mode
To recall a macro register and execute the macro in step execution mode, use
the following procedure.
1
In the Flexi Pad control block, recall the macro register.
For details of recalling macro registers, see “Recalling a Macro Register
and Executing a Macro” (page 951).
The Flexi Pad control block memory recall section is assigned to the
display of the [Take] button and macro execution status, as in the following
figure.