Clock Commands 111
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax
CLI\files\Clock.fm
DELL CONFIDENTIAL – PRELIMINARY 5/15/12 - FOR PROOF ONLY
when it ends. All times are relative to the local time zone. The start time is
relative to standard time. The end time is relative to summer time. If the
starting month is chronologically after the ending month, the system assumes
that you are in the southern hemisphere.
USA rule for daylight saving time:
• From 2007:
• Start: Second Sunday in March
• End: First Sunday in November
• Time: 2 am local time
• Before 2007:
• Start: First Sunday in April
• End: Last Sunday in October
• Time: 2 am local time
Example
console(config)#
clock summer-time
abc date apr 1 2010 09:00 aug 2 2010
09:00
EU rule for daylight saving time:
• Start: Last Sunday in March
• End: Last Sunday in October
• Time: 1.00 am (01:00) Greenwich Mean Time (GMT)
sntp authentication-key
The sntp authentication-key Global Configuration mode command defines
an authentication key for Simple Network Time Protocol (SNTP). Use the no
form of this command to remove the authentication key for SNTP.
Syntax
sntp authentication-key
key-number
md5
key-value
no sntp authentication-key
key-number

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect PC5524 and is the answer not in the manual?

Dell PowerConnect PC5524 Specifications

General IconGeneral
BrandDell
ModelPowerConnect PC5524
CategorySwitch
LanguageEnglish

Related product manuals