Manage Device Security
293
M4100 Series Managed Switch
8. In the Login Authentication List menu, specify which authentication list to use login
through Telnet.
The default value is networkList.
9. In the Enable Authentication List menu, specify which authentication list you are using
when going into the privileged EXEC mode.
The default value is enableNetList.
Configure Inbound Telnet
You can regulate new Telnet sessions. If Allow New Telnet Sessions is enabled, new inbound
Telnet sessions can be established until there are no more sessions available. If Allow New
Telnet Sessions is disabled, no new inbound Telnet sessions are established. An established
session remains active until the session is ended or an abnormal network error ends the
session.
 To configure inbound Telnet:
1. Prepare your computer with a static IP address in the 169.254.100.0 subnet, for
example, 169.254.100.201.
2. Connect an Ethernet cable from an Ethernet port on your computer to an Ethernet port on
the switch.
3. Launch a web browser.
4. Enter the IP address of the switch in the web browser address field.
The default IP address of the switch is 169.254.100.100.
The Login screen displays.
5. Enter the user name and password.
The default admin user name is admin and the default admin password is blank, that is,
do not enter a password.
6. Click the Login button.
The web management interface menu displays.
7. Select Security  Access > Telnet.

Table of Contents

Other manuals for NETGEAR M4100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR M4100 Series and is the answer not in the manual?

NETGEAR M4100 Series Specifications

General IconGeneral
BrandNETGEAR
ModelM4100 Series
CategorySwitch
LanguageEnglish

Related product manuals