[4] CHECK POINTS OF EVERY 100 HOURS
Checking Battery Condition
CAUTION
Never remove the vent plugs while the engine is running.
Keep electrolyte away from eyes, hands and clothes. If you
are spattered with it, wash it away completely with water
immediately and get medical attention.
Keep open sparks and flames away from the battery at all
times. Hydrogen gas mixed with oxygen becomes very
explosive.
Wear eye protection and rubber gloves when working
around battery.
1. The original battery is maintenance free type battery
(Non-refillable type).
When the performance becomes low, inspect the battery.
2. Clean the battery surface with a clean cloth.
Keep the terminals clean and coated with petroleum jelly.
3. Check the battery condition by reading the indicator.
(To be continued)
State of indicator display
Green
Specific gravity of electrolyte and quality of electrolyte
are both in good condition.
Black Needs charging battery.
White Needs replacing battery.
(1) Battery (2) Indicator