CABIN
M6060, M7060, WSM
9-S12
(6) T-joint
T-joint (2) is used to increase efficiency of gas charging using
two refrigerant containers (4) at a time.
1. Install two refrigerant container service valves to T-joint (2)
sides and connect the charging hose (1) to it.
9Y1210828CAS0014US0
(7) R134a Refrigerant Recover and Recycling Machine
When there is necessity of discharging the refrigerant on
repairing the tractor, it should use recovery and recycling machine.
(Do not release the refrigerant into the atmosphere.)
IMPORTANT
• Use only R134a refrigerant recovery and recycling
machine, eliminate mixing R134a equipment, refrigerant
and refrigerant oils with R12 systems to prevent
compressor damage.
9Y1210828CAS0015US0
(1) Charging Hose (Green)
(2) T-joint
(3) Can Tap Valve
(4) Refrigerant Container
KiSC issued 08, 2013 A