EasyManuals Logo

Gambro AK 98 Operator's Manual

Gambro AK 98
386 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
A:22 AK 98 Dialysis Machine - Before you get started
HCEN12745 Revision 10.2016
Program version 2.xx
NOTE!
The user should follow the facility procedures for proper disposal of used blood
lines, dialyzers and other disposables per local regulations.
1.4.2 Concentrates
Accessories mentioned in this section are approved and required for use with the
AK 98 dialysis machine.
CAUTION!
Incorrect choice of dialysis fluid concentrate may cause incorrect composition of the
dialysis fluid. Incorrect composition may lead to electrolytic imbalance in the patient's
blood.
Liquid concentrates Intended use
SOFTPAC
G- and C-series
The SOFTPAC product is an acid concentrate
for bicarbonate based hemodialysis and is
intended to be used together with the BICART
cartridge for on-line preparation of
hemodialysis, hemodiafiltration or
hemofiltration fluids on compatible Baxter
dialysis machines.
To obtain a current listing of recommended
concentrates contact your local sales office.
SOFTPAC Citrate
G- and C-series
The SOFTPAC Citrate product is intended to
be used as a citrate based acid concentrate
together with the BICART cartridge for on-line
preparation of hemodialysis, hemodiafiltration
and hemofiltration fluids on compatible Baxter
dialysis machines.
To obtain a current listing of recommended
concentrates contact your local sales office.
Table 1-2. Liquid concentrates
Non-liquid concentrates Intended use
BICART cartridge Dry bicarbonate concentrate for preparation of
bicarbonate dialysis fluid together with proper
liquid A-concentrate.
To obtain a current listing of recommended
concentrates contact your local sales office.
Table 1-3. Non-liquid concentrates
1.4.3 Chemical disinfectants
Accessories mentioned in this section are approved and required for use with the
AK 98 dialysis machine.
Chemicals suitable for disinfection and concentrations thereof are listed in Section
14.1.10 ā€œDisinfection and cleaning – chemical disinfectionā€ on pageī™›A:180. Chemical
disinfectants may be harmful to the materials used in the fluid path of dialysis
machines. Therefore it is important to use the right disinfectant and be aware of the
precautions for a certain chemical disinfectant before use, see Section 10.4.7 ā€œAbout
chemical disinfectantsā€ on pageī™›A:152.

Table of Contents

Other manuals for Gambro AK 98

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gambro AK 98 and is the answer not in the manual?

Gambro AK 98 Specifications

General IconGeneral
BrandGambro
ModelAK 98
CategoryMedical Equipment
LanguageEnglish

Related product manuals