7½ Digit Graphical Sampling Multimeter Reference Manual Section 8:
TSP command reference
DMM7510-901-01 Rev. B / May 2015 8-5
5 Where saved. Indicates where the command settings reside once they are used on an
instrument. Options include:
• Not saved: Command is not saved and must be typed each time you use it.
• Nonvolatile memory: The command is stored in a storage area in the instrument where information is
saved even when the instrument is turned off.
• Configuration script: Command is saved as part of the configuration script.
• Measure configuration list: This command is stored in measure configuration lists.
6 Default value: Lists the default value or constant for the command.
Command usage
The Usage section of the remote command listing shows how to properly structure the command.
Each line in the Usage section is a separate variation of the command usage. All possible command
usage options are shown.
Figure 163: TSP usage description
1 Structure of command usage: Shows how the parts of the command should be organized. If a
parameter is shown to the left of the command, it is the return when you print the command.
Information to the right are the parameters or other items you need to enter when setting the
command.
2 User-supplied parameters: Indicated by italics. For example, for the function
beeper.beep(duration, frequency), replace duration with the number of seconds and
frequency with the frequency of the tone. beeper.beep(2, 2400) generates a two-second,
2400 Hz tone.
Some commands have optional parameters. If there are optional parameters, they must be
entered in the order presented in the Usage section. You cannot leave out any parameters that
precede the optional parameter. Optional parameters are shown as separate lines in usage,
presented in the required order with each valid permutation of the optional parameters.
For example:
printbuffer(startIndex, endIndex, buffer1)
printbuffer(startIndex, endIndex, buffer1, buffer2)
3 Parameter value options: Descriptions of the options that are available for the user-defined
parameter.
Command details
This section lists additional information you need to know to successfully use the remote commands.
Figure 164: TSP Details description

Table of Contents

Other manuals for Keithley DMM7510

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley DMM7510 and is the answer not in the manual?

Keithley DMM7510 Specifications

General IconGeneral
BrandKeithley
ModelDMM7510
CategoryMultimeter
LanguageEnglish

Related product manuals