EasyManuals Logo
Home>Keithley>Multimeter>DMM7510

Keithley DMM7510 Reference Manual

Keithley DMM7510
1036 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #991 background imageLoading...
Page #991 background image
Section
9: Frequently asked questions (FAQs) Model DMM7510 7½ Digit Graphical Sampling Multimeter
Reference Manual
9-8 DMM7510-901-01 Rev. B / May 2015
How do I save the present state of the instrument?
You can save the settings in the instrument as a script using the front-panel menus or from a remote
interface. After they are saved, you can recall the script or copy it to a USB flash drive.
From the front panel:
1. Configure the Model DMM7510 to the settings that you want to save.
2. Press the MENU key.
3. Under Scripts, select Create Setup. The CREATE SETUP window is displayed.
4. Select Create. A keyboard is displayed.
5. Use the keyboard to enter the name of the script.
6. Select the OK button on the displayed keyboard. The script is added to internal memory.
Using SCPI commands:
Configure the instrument to the settings that you want to save. To save the setup, send the
command:
*SAV <n>
Where <n> is an integer from 0 to 4.
In the front-panel script menus, the setups saved with the *SAV command have the name Setup0x,
where x is the value you set for <n>.
Using TSP commands:
Configure the instrument to the settings that you want to save. To save the setup, send the
command:
createconfigscript("setupName")
Where setupName is the name of the setup script that will be created.
Why did my settings change?
Many of the commands in the Model DMM7510 are saved with the measure function that was active
when you set them. For example, assume you have the measure function set to current and you set a
value for display digits. When you change the measure function to voltage, the display digits value
changes to the value that was last set for the voltage measure function. When you return to the
current measure function, the display digits value returns to the value you set previously.
What is offset compensation?
Offset compensation is a measuring technique that reduces or eliminates thermoelectric EMFs in
low-level resistance measurements. The voltage offsets because of the presence of thermoelectric
EMFs (V
EMF
) can adversely affect resistance measurement accuracy.
To overcome these offset voltages, you can use offset-compensated ohms.

Table of Contents

Other manuals for Keithley DMM7510

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley DMM7510 and is the answer not in the manual?

Keithley DMM7510 Specifications

General IconGeneral
BrandKeithley
ModelDMM7510
CategoryMultimeter
LanguageEnglish

Related product manuals