7.3.3.1 Simulaon of the virtual master
The technology interface is operated manually via the following parameters:
Simulaon of control signals virtual master 40x5045:001
Simulaon of status signals 40x5045:101
Bit 0 of the Simulaon of control signals virtual master par
ameter acvates manual opera-
on of the technology funcon. All control words are set to manual operaon. 40x5045:001
Bit 0
The setpoint velocity can be switched over to system bus/eldbus operaon via bit 1 of the
Simulaon of control signals virtual master. 40x5045:001
Bit 0 of the Simulaon of status signals par
ameter acvates the interface simulaon. All sta-
tus words are switched over to manual operaon. 40x5045:101 Bit
0
Status word 00:
-Bit 3 (VM Fault)
-Bit 6 (VM Jogging Busy)
-Bit 7 (VM Warning)
-Bit 8 (VM Halt Busy)
-Bits 25-31
0x50 : 145 1 0
0x50 :45 111
0x50 :45 112
0x50 :45 113
0x50 :45 114
0x50 :45 115
Virtual
Master
Control word 02
Control word 00
0x50 :01145
0x50 :01045
0x50 : 1:Bit 045 10
0x50 :001:Bit 145
0x50 :001:Bit 045
Fieldbus/System bus
Fieldbus/System bus
Technology application/Main Technology
Fig. 43: Basic signal ow
Parameter
Address Name / seng range / [default seng] Info
0x5045:001 Simulaon of control signals virtual master
0x00 ... [0x00] ... 0xFF
Bit 0 Enable control signal simulaon TRUE:
Simulaon of control word is acvated.
FALSE: The control word is transmied via the acve network interface.
Bit 1 Acvate simulaon of control word 1 TRUE: Simulaon of control word 1 is acvated.
FALSE: The control word is transmied via the acve network interface.
Bit 2 Acvate simulaon of control word 2 TRUE: Simulaon of control word 2 is acvated.
FALSE: The control word is transmied via the acve network interface.
Bit 3 Acvate simulaon of control word 3 TRUE: Simulaon of control word 3 is acvated.
FALSE: The control word is transmied via the acve network interface.
Bit 4 Acvate simulaon of control word 4 TRUE: Simulaon of control word 4 is acvated.
FALSE: The control word is transmied via the acve network interface.
Bit 5 Acvate simulaon of control word 5 TRUE: Simulaon of control word 5 is acvated.
FALSE: The control word is transmied via the acve network interface.
Bit 6 Acvate simulaon of control word 6 TRUE: Simulaon of control word 6 is acvated.
FALSE: The control word is transmied via the acve network interface.
Bit 7 Acvate simulaon of control word 7 TRUE: Simulaon of control word 7 is acvated.
FALSE: The control word is transmied via the acve network interface.
0x5045:101 Simulaon of status signals
0x00 ... [0x00] ... 0xFF
Bit 0
Conguring the "Electronic Gearbox" TA
Mas
ter value sources
Virtual master
110

Table of Contents

Other manuals for Lenze I95AE240F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze I95AE240F and is the answer not in the manual?

Lenze I95AE240F Specifications

General IconGeneral
BrandLenze
ModelI95AE240F
CategoryInverter
LanguageEnglish

Related product manuals