Address Name / seng range / [default seng] Info
0xA680:009 Systembus input data: Systembus data input 9
0 ... [0] ... 4294967295
0xA680:010 Systembus input data: Systembus data input 10
0 ... [0] ... 4294967295
0xA680:011 Systembus input data: Systembus data input 11
0 ... [0] ... 4294967295
0xA680:012 Systembus input data: Systembus data input 12
0 ... [0] ... 4294967295
0xA680:013 Systembus input data: Systembus data input 13
0 ... [0] ... 4294967295
0xA680:014 Systembus input data: Systembus data input 14
0 ... [0] ... 4294967295
0xA680:015 Systembus input data: Systembus data input 15
0 ... [0] ... 4294967295
0xA680:016 Systembus input data: Systembus data input 16
0 ... [0] ... 4294967295
16.4.4 Monitoring
Monit
oring of the master/slave funconality
The following scenarios are monitored:
•
The in
verter at posion 1 is not congured as system bus master.
•
Se
veral inverters have been congured as system bus master.
Depending on the assignment of the system bus interfaces X246 (EtherCAT IN) and X247
(EtherCAT OUT) and the set interface role in 0x2371:009 (master/slave), a warning is output:
Network cable plugged in X246/X247 0x2371:009 = 0
(Sla
ve)
0x2371:009 = 1
(Master)
Only X246 (EtherCAT IN) is assigned. OK Warning
Only X247 (EtherCAT OUT) is assigned. Warning OK
X246 (EtherCAT IN) and X247 (EtherCAT OUT) are assigned. OK Warning
The parameters for seng network monitoring funcons are described below.
Parameter
Address Name / seng range / [default seng] Info
0x285B:001 EtherCAT system bus monitoring: Watchdog abgelau-
f
en
0 No response
1 Fault > CiA402
2 Warning
0x285B:002 EtherCAT system bus monitoring: EtherCAT role check
0 No response
1 Fault > CiA402
2 Warning
Conguring the network
E
therCAT system bus
Monitoring
348