12.2.2 Resolver sengs
Resolvers with a number of pole pairs > 1 are not absolute value encoders.
Bit 10 in (Lenz
e status word 2) therefore remains set to "0".
The "disnguishable revoluons" specicaon in 0x2C56 is also set to "0".
Parameter
Address Name / seng range / [default seng] Info
0x2822:029 Axis commands: Get load encoder/master encoder
characterisc (resolver)
Denion of the resolver
characterisc for applicaon feedback.
0 O / ready Only status feedback
1 On / start Execute device command
2 In progress Only status feedback
3 Acon cancelled
4 No access
5 No access (Inverter disabled)
0x2C53 Load encoder/master encoder resolver number of
pole pair
s
1 ... [1] ... 1
Seng can only be changed if the inverter is inhibi-
ted.
Seng of the number of pole pairs.
Conguring the feedback system
Sec
ond feedback system for the techology applicaon
Resolver sengs
190