7.4 External torque limitaon
The external torque limit is dened via the Ext
ernal torque limit parameter. 40x5040:017
The external torque limit is acvated with bit 22 of the Control signal parameter.
40x5040:010
Bit 22 of the Status signals parameter indicates whether the external torque limit is acve.
Bit 22
As long as the external torque limit remains inacve, the two parameters Posive torque limit
and Negave torque limit dene what torque limits apply.
Posive torque limit 40x500A:128
Negave torque limit 40x500A:129
The
funcon mode of the external torque limit is set via the Impact of external speed limit
parameter.
The following sengs are possible via this parameter:
0x60E1
0x60E0
5040:010 (Bit 31)
5040:017
0x500A:128
5040:017
0x500A:129
Fig. 48: 0x5040:003 = 0: Seng aects the posive and negave torque limit
5040:010 (Bit 31)
0x500A:129
0x60E1
0x500A:128
5040:017
0x60E0
Fig. 49: 0x5040:003 = 1: Seng aects the posive torque limit
5040:010 (Bit 31)
0x500A:128
0x60E0
0x500A:129
5040:017
0x60E1
Fig. 50: 0x5040:003 = 2: Seng aects the negave torque limit
Conguring the "Electronic Gearbox" TA
Ex
ternal torque limitaon
115

Table of Contents

Other manuals for Lenze I95AE240F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze I95AE240F and is the answer not in the manual?

Lenze I95AE240F Specifications

General IconGeneral
BrandLenze
ModelI95AE240F
CategoryInverter
LanguageEnglish

Related product manuals