9.6.7 Extension for the digital inputs DI3 and DI4
The content of this secon is currently being processed.
Parameter
Address Name / seng range / [default seng] Info
0x2D02:001 Touch probe diagnoscs: Touch probe 3/4 funcon
0x0000 ... [0x0000] ... 0xFFFF
Bit 0 Acvate touch probe 3
Bit 1 Touch probe 3 trigger = 1st
event/connous
Bit 2 Touch probe 3 source = TP input/zero pulse
Bit 4 Touch probe 3 sampling = rising edge
Bit 5 Touch probe 3 sampling = falling edge
Bit 6 Posion feedback source
Bit 8 Acvate touch probe 4
Bit 9 Touch probe 4 trigger = 1st event/connous
Bit 10 Touch probe 4 source = TP input/zero pulse
Bit 12 Erfassung Touch-Probe 4 = steigende Flanke
Bit 13 Erfassung Touch-Probe 4 = fallende Flanke
Bit 14 Posion feedback source
0x2D02:002 Touch probe diagnoscs: Touch-Probe 3/4 status
Read only
Bit 0 Touch-Probe 3 ist akviert
Bit 1 Touch-Probe 3 - Posion erfasst fallende
Flanke
Bit 2 Touch-Probe 3 - Posion erfasst steigende
Flanke
Bit 6 Touch-Probe 3 - Pegel bei Zeitstempel
Bit 8 Touch-Probe 4 ist akviert
Bit 9 Touch-Probe 4 - Posion erfasst fallende
Flanke
Bit 10 Touch-Probe 4 - Posion erfasst steigende
Flank
e
Bit 14 Touch-Probe 4 - Pegel bei Zeitstempel
0x2D03:001 Touch probe posion: Touch probe 3 posion rising
edge
Read only: x pos. unit
0x2D03:002 Touch probe posion: Touch probe 3 posion falling
edge
Read only: x pos. unit
0x2D03:003 Touch probe posion: Touch probe 4 posion rising
edge
Read only: x pos. unit
0x2D03:004 Touch probe posion: Touch probe 4 posion falling
edge
Read only: x pos. unit
9.6.8 Detected me stamp and posions
In case of the
"connuous touch probe conguraon", a newly detected value
overwrites the previously detected value.
Parameter
Address Name / seng range / [default seng] Info
0x2D01:001 Touch probe (TP) me stamp: Touch probe 1-rising
edg
e me stamp
Read only: x ns
Display of the me stamp of the rising edge for touch probe 1.
0x2D01:002 Touch probe (TP) me stamp: Touch probe 1-falling
edge me stamp
Read only: x ns
Display of the me stamp of the falling edge for touch probe 1.
Congure posion control
Posion
detecon with touch probe (TP)
Extension for the digital inputs DI3 and DI4
145

Table of Contents

Other manuals for Lenze I95AE240F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze I95AE240F and is the answer not in the manual?

Lenze I95AE240F Specifications

General IconGeneral
BrandLenze
ModelI95AE240F
CategoryInverter
LanguageEnglish

Related product manuals