6.3.4 Source of monitoring signal
A monitoring signal can be selected for control word 6 and control word 7.
The source for the monitoring signal to be output is selected via the Sour
ce for monitoring
signal parameter. The number of decimal posions transferred depends on the value selected.
•
Selecon for control word 6: 40x5040:006
•
Selecon for control word 7: 40x5040:007
The source for the monitoring signal to be output is selected via the Source for monitoring
signal parameter. The number of decimal posions transferred depends on the value selected.
0x5030:006
0x50 0:0064
(Source onitoring ignal )m s 1
None
Actual motor temperature
Actual motor current
DC bus voltage
Thermal load device
Termmal load motor
Analog input
0x50 0:1164
(Monitoring ignal )s 1
Velocity offset total
Fig. 23: Selecon of digital output
0x50 0:0074
(Source onitoring ignal )m s 2
None
Actual motor temperature
Actual motor current
DC bus voltage
Thermal load device
T mal load motorher
Analog input
0x50 0: 11 74
(Monitoring ignal )s 2
Velocity offset total
Fig. 24: Selecon of digital output
Parameter
Address Name / seng range / [default seng] Info
0x5040:006 Display value 1 Signal selecon for the monitoring of signal 1 to status word 6.
Signal selecon for the monitoring of signal 2 to status word 7.
0 None Signal selecon for the monitoring of signal 1 to status word 6.
1 Actual motor temperature
2 Actual motor current
3 DC-bus voltage
4 Device ulisaon
5 Motor ulisaon
6 Analog input 1
13 Total velocity oset
Technology applicaon (TA) basic sengs
Dening control sources
Sour
ce of monitoring signal
82