19.12 Safely-Limited Posion (SLP)
The funcon monitors the lower and upper posion limit.
Precondions
The following funcon must be executed:
•
Se
t upper
posion value.
•
Set lower posion value.
•
Safe homing (SHOM)
Funconal descripon
t
0
SLP observed
P
STO/SS1/SS2
0x28D2:004
...
0x28D2:001
0x28D3:004
...
0x28D3:001
0x28D4:004
...
0x28D4:001
Fig. 74: SLP funcon
For operaon within the upper limit value, the SLPpos observed status is used. 0x28D3:000
F
or operaon within the lower limit value, the SLPneg observed status is used. 0x28D2:000
The upper and lower posion limits parameterised are monitored at the me of the request,
see SLPx observed status bit.
The status can
•
be assigned to the safe output (0x28BB:0010x28BB:001 or 0x28BB:0020x28BB:002).
•
be reported via the safety bus (0x28B9:0010x28B9:001 or 0x28BB:0020x28B9:002).
This funcon can be executed during normal operaon and special operaon. See 4Oper
a-
on mode selector (OMS) . ^ 410
Up to four absolute posion setpoint pairs can be parameterised and monitored at the same
me.
In
connecon with this funcon, please also observe the informaon with
regard to safe homing in chapter Safe homing (SHOM).
Via a safe input, if the corresponding parameter is assigned to the safe input.
Acvaon of the
funcon
A data telegram is sent to the inverter via the safety bus. See chapter "Safe network interfa-
ces". ^ 417
Behaviour of the funcon in the event of an error
If the Plim posion limit is exceeded during the monitoring process,
•
an err
or message is triggered.
•
a stop funcon for the parameters set
-
0x28D2:0010x28D2:001 ... 0x28D2:0040x28D2:004 the lower absolute posion limit
set
-
0x28D3:0010x28D3:001 ... 0x28D3:0040x28D3:004 the upper absolute posion limit
set
is triggered.
Safety funcons
Safely-Limited Posion (SLP)
398