19.2 Safe Emergency Stop (SSE)
The SSE safety funcon has the highest priority. The SSE safety funcon is primarily triggered
fr
om all states, operang modes or safety funcons. Depending on the parameter seng in
0x28A3:0010x28A3:001, the emergency stop funcon acvates one of the funcons:
4Safe Torque O (STO)
4Sa
fe Stop 1 (SS1)
NOTICE
Emergency stop buons must not be overruled by a special operaon.
Otherwise the
funconal safety of the system cannot be guaranteed anymore.
▶
Please observe the notes in the secon
.
▶
Please observe the notes regarding the special operaon (OMS) in the secon
4
Operaon mode selector (OMS). ^ 410
Precondions
The emergency stop buons are connected to the emergency stop funcon.
Details
The
funcon is acvated by the following:
•
a da
ta telegram with a corresponding content is sent to the inverter via the safety bus.
•
"OFF state" at a safe input which has been assigned to the funcon by parameterisaon.
Via a safe input, if the corresponding parameter is assigned to the safe input.
Acvaon of the
funcon
A data telegram is sent to the inverter via the safety bus. See chapter "Safe network interfa-
ces". ^ 417
Parameter
Address Name / seng range / [default seng] Info
0x28A1 SSE: Source SD-In
•
R
ead only
0 Deacvated
1 SD-In1
2 SD-In2
3 SD-In3
4 SD-In4
0x28A2 SSE: Source S-Bus
•
Read only
0 Deacvated
1 Acvated
0x28A3:001 SSE: SSE: Emergency Stop funcon
•
R
ead only
0 STO
1 SS1
0x28A4 SSE acve: Output
•
R
ead only
0 Deacvated
1 SD-Out1 posive logic
2 SD-Out1 negave logic
Safety
funcons
Safe Emergency Stop (SSE)