8 Start, stop and rotang
direcon commands
8.1 Control selecon
Parameter
Address Name / seng range / [default seng] Info
0x2824 Control selecon
Seng can only be changed if the inverter is inhibi-
t
ed.
Selecon of the type of inverter control.
0 Flexible I/O conguraon This selecon enables a exible assignment of the start, stop, and rotat-
ing direcon commands with digital signal sources.
Digital signal sources can be digital inputs, network and keypad.
The I/O conguraon is made via the parameters 0x2631:xx (P400.xx).
1 Keypad This selecon enables the motor to be started exclusively via the start
k
ey of the keypad. Other signal sources for starng the motor are
ignored.
Start motor Stop motor
Not
e!
The funcons "Enable inverter" and "Run" must be set to TRUE to
start the motor.
If jog operaon is acve, the motor cannot be stopped via the
keypad key.
Start, stop and rotang
direcon commands
Control selecon