13.11.2 Manual "tension/frequency" test mode
Funconal
descripon
In case of devices that correspond to the "dual use regulaon" (EC 428/2009),
v
alues higher than + 599 Hz up to lower than - 599 Hz do not increase the out-
put frequency. Please observe the deadband occurring in this case.
Further informaon can be found in the secon "Frequency and speed limita-
ons". ^ 276
Aer the controller is enabled in this test mode, a rotary eld voltage is output at the motor
terminals with the set output frequency f
out
.
If the select
ed frequency is
posive, the motor should rotate clockwise when looking at
the A side of the motor. If this is not the case, the motor phases are connected incorrectly.
The output voltage level is determined by the following equaon
Equaon for calculang the output voltage
rated
out out
rated
U
U f
f
= ×
Parameter Symbol Descripon Dimension unit
V
out
Current output voltage V
0x2835:002 f
out
Output frequency for test mode
Please observe the notes in the
secon "Frequency and speed limi-
taons". ^ 276
Hz
0x2B01:001 V
rated
Base voltage V
0x2B01:002 f
rated
Base frequency Hz
The manual "voltage / frequency" test mode also serves to check the wiring of the feedback
s
ystem.
If the f
eedback system of a synchronous motor is set correctly, an actual speed should be
displayed that can be calculated with the following equaon (if the feedback system of an
as
ynchronous motor is set correctly, the actual speed is a bit lower due to the slip):
Equaon for calculang the actual speed
out
act
motor
f
n 60
zp
= ×
Parameter Symbol Descripon Dimension unit
0x606C n
act
Velocity actual value
rpm
0x2835:002 f
out
Output frequency for test mode Hz
0x2C01:001 zp
Mot
or
Number of motor pole pairs
Condions for the execuon
The mot
or must rotate freely.
The servo inverter is error-free and in the "switched-on" device state.
Response of the motor during performance
The motor moves as a
funcon of the set output frequency.
How to acvate the manual "voltage/frequency" test mode:
1.
Disable the in
verter 4Enable operaon. ^ 296
2.
Chang
e to the "voltage/frequency" test mode. 40x2825 = 1
3.
Enable the inverter to start the test mode.
4.
To stop the test mode again:
Disable inverter.
Change back to the "CiA402 operang mode". 40x2825 = 0
Conguring the motor control
Tesng the motor control
Manual "t
ension/frequency" test mode
279

Table of Contents

Other manuals for Lenze I95AE240F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze I95AE240F and is the answer not in the manual?

Lenze I95AE240F Specifications

General IconGeneral
BrandLenze
ModelI95AE240F
CategoryInverter
LanguageEnglish

Related product manuals