Parameter
Address Name / seng range / [default seng] Info
0x4000 Applicaon
selecon
•
Seng can only be changed if the inverter is inhibi-
ted.
0 "CiA 402" technology applicaon
10 "Speed Control" technology applicaon
20 "Table Posioning" technology applicaon
40 "Electronic Gearbox" technology applica-
on
41 "Sync and Correcon" technology applica-
on
50 "Winder Dancer" technology applicaon
51 "Winder Tension" technology applicaon
10000 "User" technology applicaon
7.1 Control sengs
General variables such as starng values, reference variables, and signal sources must be
dened before the control system of the technology applicaon is congured.
Sengs in "EASY Starter":
•
Sengs tab
•
T
echnology applicaon parameter dialogue for
•
Applicaon selecon 40x4000
Relevant parameters of other funcons
Address Designaon Default seng Seng range
0x4001 Interface
selecon Fieldbus network [0] Selecon list
0x5020:007 Applicaon quick stop source FALSE [0] Selecon list
0x5020:008 Source of fault reset FALSE [0] Selecon list
0x5020:014 Master value source System bus [0] Selecon list
0x5020:030 Source of digital output 1 Ready to switch on [0] Selecon list
0x5040:006 Display value 1 None [0] Selecon list
Conguring the "Electronic Gearbox" TA
Con
trol sengs
92