14.3 Congure digital outputs
14.3.1
Digital output 1
Sengs for digital output 1.
Details
The digital output 1 is controlled with the trigger selected in .
The following sengs are possible for the digital output:
•
Inversion
①
•
Manual I/O control
②
0x2634:002Trigger
0
1
0
1
1 DO1
0x4016:005 0x60FE 0x2635:002 0x263C:001
X3
0x263C:002
Diagnosc parameters:
•
Displa
y of the logic state of the trigger signal:
•
Display of the logic state of the digital output: 0x4016:005
Inversion
The trigger signal of the digital output can be internally inverted logically.
Manual I/O control
The digital output can be overridden manually. Aer the funcon is acvated, the actual val-
ues are "frozen". Aerwards, each digital output can be overwrien manually.
Seng:
•
Acvaon: 0x263C:001
•
Entering the manual value: 0x263C:002
Parameter
Address Name / seng range / [default seng] Info
0x2635:002 Inversion of digital outputs: Digital output 1 Inversion of digital output 1
0 Not inverted
1 Inverted
0x4016:005 Digital output 1: Terminal state
•
R
ead only
Display of the logic state of output terminal X3/DO1.
0 FALSE
1 TRUE
0x263C:001 Digital outputs internal control: Acvaon
0 Aus
1 Ein
0x263C:002 Digital outputs internal control: DO1 internal control
0 Aus
1 Ein
I/O extensions and control connecons
Congure digital outputs
Digit
al output 1