6.2.9 Manual jog (inching mode)
The "manual jog" funcon enables manual traversing of the drive ("inching mode").
"Manual jog" can be acvated via 2 control signals in the technology applicaon. "Manual jog"
is possible in the posive and negave
direcons.
As long as the c
ontrol bit is set, the drive moves.
If both requests are set simultaneously, the drive stops.
If the reference is known and the soware limit switches are acvated, posioning to the
c
orresponding soware limit switch is carried out.
Excepon: If the manual jog has been stopped manually before this by reseng the con-
trol inputs, a posioning to the corresponding soware limit switch is aborted.
The drive brakes with the set deceleraon to the posion of the corresponding hardware
limit switch.
If the reference is not known or the soware limit switches are not acvated, the axis only
stops at the hardware limit switch.
Parameter
Address Name / seng range / [default seng] Info
0x500A:181 Manual jog velocity
0.0000 ... [360.0000] ... 214748.3647
0x500A:182 Manual jog acceleraon
0.00 ... [720.00] ... 21474836.47
0x500A:183 Manual jog deceleraon
0.00 ... [1440.00] ... 21474836.47
0x500A:184 Manual jog jerk
0.00 ... [0.00] ... 21474836.47
Technology applicaon (TA) basic sengs
Moon
sengs
Manual jog (inching mode)
58

Table of Contents

Other manuals for Lenze I95AE240F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze I95AE240F and is the answer not in the manual?

Lenze I95AE240F Specifications

General IconGeneral
BrandLenze
ModelI95AE240F
CategoryInverter
LanguageEnglish

Related product manuals