statistics period service-accounting
To set collection period for statistics collectors, use the statistics period service-accounting command in
Global Configuration mode or Admin Configuration mode. To disable this behavior, use the no form of this
command.
statistics period service-accounting {period| disable}
no statistics period service-accounting {period| disable}
Syntax Description
Collection period in seconds. The range is from 30 to 3600. The default is
900.
period
Disables periodic statistics collection.disable
Command Default
Default collection period is 900 seconds.
Command Modes
Global Configuration mode
Command History
ModificationRelease
This command was introduced.Release 4.3.1
Usage Guidelines
To use this command, you must be in a user group associated with a task group that includes appropriate task
IDs. If the user group assignment is preventing you from using a command, contact your AAA administrator
for assistance.
Task ID
OperationTask ID
read, writediag
Examples
This example shows how to change the collection period or polling interval for statistics collector:
RP/0/RSP0/CPU0:router(config)# statistics period service-accounting 2000
Cisco ASR 9000 Series Aggregation Services Router Broadband Network Gateway Command Reference,
Release 5.2.x
62
BNG AAA Commands
statistics period service-accounting