3.5.2.1 poe pse usage
Description
With this command, you set a value (as a percentage) for the "Usage Threshold" parameter.
This specifies how many percent of the maximum power the connected devices will use. As
soon as the power being used by the end devices exceeds this percentage, an event is
triggered. An event is also entered in the log. You display the entries of the log with the
command show logbook. You will find more information on this command in the section
"show logbook (Page 546)".
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
poe pse <integer (1-4)> usage <integer (1-100)>
The parameters have the following meaning:
Parameter Description Range of values / note
integer Number of the PSE 1 … 4
integer Value for "Usage Threshold" as a per‐
centage.
1 ... 100
Default: 80%
Result
The value for "Usage Threshold" is configured.
3.5.2.2 no poe pse usage
Description
With this command, you reset the parameter "Usage Threshold" to the default value.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Configuration
3.5 PoE
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
112 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals