Syntax
Call up the command with the following parameters:
sntp unicast-server ipv4 <ucast_addr> [port<1025-36564>]
[poll<seconds(16-16284)>]
The parameters have the following meaning:
Parameter Description Range of values / note
ipv4 Keyword for an IP address -
ucast_addr Value for an IPv4 unicast address Enter a valid IPv4 unicast address.
port UDP port of the time server 1025 … 36564
Default: 123
poll Keyword for the time after which the
time of day is requested again
-
seconds Value for the time in seconds 16 ... 16284
Result
The SNTP unicast server is configured.
Further notes
You can reset the setting to the default with the no sntp unicast-server ipv4 command.
You display this setting and other information with the show sntp unicast–mode
status command.
5.3.3.4 no sntp unicast-server ipv4
Description
With this command, you delete the attributes for an SNTP unicast server and reset the
address.
Requirement
You are in the SNTP configuration mode.
The command prompt is as follows:
cli(config-sntp)#
Syntax
Call up the command with the following parameters:
no sntp unicast-server ipv4<ucast_addr>
System time
5.3 SNTP client
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 159

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals