7.5.2.15 no snmp targetaddr
Description
With this command, you delete the SNMP target address.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no snmp targetaddr <TargetAddressName>
The parameter has the following meaning:
Parameter Description Range of values / note
TargetAddressName SNMP target address max. 32 characters
Result
The SNMP target address is deleted.
Further notes
You change the SNMP target address with the snmp targetaddr command.
You display the SNMP target address with the show snmp targetaddr command.
7.5.2.16 snmp targetparams
Description
With this command, you configure the SNMP target parameters.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Network protocols
7.5 SNMP
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 343

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals