Syntax
Call the command without parameters:
spanning-tree loop-guard
Result
The "Spanning Tree Loop Guard" function is enabled.
Further notes
You disable the setting with the no spanning-tree loop-guard command.
You can display the status of this function and other information with the following commands:
show spanning-tree detail
show spanning-tree active detail
show spanning-tree interface
6.3.5.11 no spanning-tree loop-guard
Description
This function prevents alternative ports or root ports becoming designated ports if there is a
disruption of a one-way link.
With this command, you disable the function.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no spanning-tree loop-guard
Result
The "Spanning Tree Loop Guard" function is disabled.
Further notes
You enable the setting with the spanning-tree loop-guard command.
Network structures
6.3 Spanning Tree
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
250 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals