Parameter Description Range of values / note
risingevent-
number
Event number for this 1 ... 65535
falling-threshold Keyword for threshold value for falling
or low variable values
-
value Relevant threshold value 0 ... 2147483647
fallingevent-
number
Event number for this 1 ... 65535
owner User to which the alarm is assigned -
ownername User name of the user max. 127 characters
If you do not select a parameter from the parameter list, the events for high and low threshold
values are assigned the lowest event number available in the event table.
Note
MIB variables that can be monitored
With the RMON function, only MIB variables of the Ethernet interfaces can be monitored.
Note
Magnitude of the threshold values
The threshold value for falling or low variable values should be less than the threshold value
for rising or high variable values.
Note
Conditions for working with alarms
The events assigned to the alarms are configured.
The Remote monitoring function is started with the rmon command.
Result
The alarm for monitoring a MIB variable is configured.
Further notes
You delete an alarm with the no rmon alarm command.
You display the list of configured RMON alarms with the show rmon alarms command.
12.4.2.4 no rmon alarm
Description
With this command, you delete an alarm for monitoring a MIB variable.
Diagnostics
12.4 RMON
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface