3.1.7 logout
Description
With this command, you exit the Command Line Interface.
If you are connected to the device via telnet, the session is closed.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
logout
Result
The CLI session is ended and the Windows Login prompt is displayed.
3.1.8 ping
Description
With this command, you request a response from a device in the network.
This allows you to check whether or not another node is reachable.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call up the command with the following parameters:
ping <destination-address>
[size<byte(0-2080)>]
[count<packet_count(1-10)>]
[timeout<seconds(1-100)>]
Configuration
3.1 System
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 63

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals