Result
The setting is enabled.
Further notes
You can reset the setting to the default with the no switchport acceptable-frame-
type command.
You can display the status of this function and other information with the show vlan port
config command.
6.1.3.4 no switchport acceptable-frame-type
Description
With this command, you reset the setting for the types of frames accepted by the interface to
the default value.
The default value is all.
The interface accepts tagged and untagged frames.
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no switchport acceptable-frame-type
Result
The setting is reset to the default value.
Further notes
You configure the setting with the switchport acceptable-frame-type command.
You can display the status of this function and other information with the show vlan port
configcommand.
Network structures
6.1 VLAN
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 181

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals