The parameters have the following meaning:
Parameter Description
manual The system time is entered by the user
ntp The system time is obtained from an NTP server
sntp The system time is obtained from an SNTP server
SINEC The system time is obtained using the "SIMATIC time protocol"
Result
The method of obtaining the system time is configured.
Further notes
You display the settings for the system clock with the show time command.
5.1.2.2 time set
Description
With this command, you set the system clock.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
time set hh:mm:ss <day (1-31)> {january|february|march|april|may|
june|july|august|september|october|november|december}
<year (2000 - 2035)>
The parameters have the following meaning:
Parameter Description Range of values / note
hh:mm:ss Time of day Hour, minute, second each sepa‐
rated by ":" no link
day Day of the month 1 ... 31
- Month january, february, march, april,
may, june, july, august, septem‐
ber, october, november, december
year Year 2000 ... 2035
System time
5.1 System time setting
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 145

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals