The RADIUS authentication is deactivated.
Note
The login is possible only with a local user name and password. If the local logon fails, there
is no authentication via a RADIUS server.
Further notes
You enable the authentication via a RADIUS server with the login authentication
command.
11.2.2.3 radius-server
Description
With this command, you configure a RADIUS server entry on the RADIUS client.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
radius-server ipv4 <ipv4-address> [auth-port <portno(1-65535)>]
[retransmit <1-254>][key <secret-key-string>][primary] [{login |
dot1x | login-dot1x}] [test]
The parameters have the following meaning:
Parameter Description Range of values / note
ipv4 Keyword for an IPv4 address. -
ipv4-address Value for the IPv4 address of the Syslog
server
Enter a valid IPv4 address.
auth-port Keyword for the UDP port number for
authentication
-
portno Number of the port 1 … 65535
Default: 1812
retransmit Keyword for the number of connection
retries
-
Security and authentication
11.2 RADIUS client
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 509

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals