EasyManuals Logo
Home>Siemens>Switch>SCALANCE XR-300WG

Siemens SCALANCE XR-300WG User Manual

Siemens SCALANCE XR-300WG
618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #582 background imageLoading...
Page #582 background image
Parameter Description Range of values / note
event-description Description of the event that is output in
the message.
max. 127 characters
owner Keyword for the person responsible -
ownername Name of the person responsible max. 127 characters
trap Keyword for selecting an SNMP notifi‐
cation
-
notify Name of the SNMP notification to be
triggered.
The only valid entry allowed is
"SNMPv1Traps".
You can configure the sending of
traps globally with the command
snmp notify.
Result
The event is configured.
Further notes
You delete an entry with the no rmon event command.
You display the RMON Event Table with the show rmon events command.
You show the details of the SNMP community with the show snmp community command.
12.4.2.6 no rmon event
Description
With this command, you delete an entry from the RMON event table.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no rmon event <number (1-500)>
The parameter has the following meaning:
Parameter Description Range of values / note
number Number of the event entry to be deleted 1 ... 500
Diagnostics
12.4 RMON
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
582 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals