cli(config-dhcp-pool-<ID>)#
Syntax
Call up the command with the following parameters:
relay-information <remote-id> <circuit-id>
The parameters have the following meaning:
Parameter Description Range of values / note
remote-id Remote ID of the device Enter the remote ID of the de‐
vice.
circuit-id Circuit ID of the device. Enter the circuit ID of the device.
Result
Devices with a certain remote ID and circuit ID are assigned the IPv4 addresses from a specific
address band. Before the IPv4 address band can be used, it still needs to be activated.
Further notes
You cancel the assignment with the no relay-information command.
You display the setting with the show ip dhcp relay information command.
You enable the IPv4 address band with the pool-enable command.
7.3.3.11 no relay-information
Description
With this command you cancel the assignment of devices with a certain remote ID and circuit
ID to IPv4 addresses from a specific address band.
Requirement
You are in the DHCPPOOL configuration mode.
The command prompt is as follows:
cli(config-dhcp-pool-<ID>)#
Syntax
Call up the command with the following parameters:
no relay-information <remote-id> <circuit-id>
Network protocols
7.3 DHCP server
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 303

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals