8.4.6.11 no standby wait-for-partner
Description
With this command, you disable the "Wait for standby partner" function on the device. A
standby connection is enabled even if the standby master has not yet established a connection
to the standby slave.
Requirement
You are in the Redundancy configuration mode.
The command prompt is as follows:
cli(config-red)#
Syntax
Call the command without parameters:
no standby wait-for-partner
Result
The "Wait for standby partner" function is disabled.
Layer 2 management protocols
8.4 Ring redundancy and standby connection
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
408 Configuration Manual, 07/2017, C79000-G8976-C361-06