Result
PoE is activated for the corresponding interface.
3.5.3.2 no poe active
Description
With this command, you deactivate PoE for the interface in whose interface configuration mode
you are currently working.
Requirement
You are in the Interface Configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no poe active
Result
PoE is deactivated for the corresponding interface.
3.5.3.3 poe custom maxpwr
Description
With this command you set the maximum power that a port makes available to supply a
connected device.
This value is taken into account when the function is enabled with the poe custom maxpwr
active command.
Requirement
You are in the Interface Configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameter:
Configuration
3.5 PoE
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
114 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals