The parameters have the following meaning:
Parameter Description
low low priority
high high priority
critical highest priority
If the power of the connected power supply is inadequate to supply all connected devices,
devices with a higher priority are given preference.
If the same priority is set for two ports, the port with the lower number will be preferred when
necessary.
Result
The priority of the corresponding interface has been specified.
3.5.3.10 no poe prio
Description
With this command, you set the priority of an interface to the default value "low".
Requirement
You are in the Interface configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no poe prio
Result
The priority of the corresponding interface has been set to "low".
Configuration
3.5 PoE
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 119

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals