Further notes
You configure the user-defined maximum power for the interface with the poe custom
maxpwr command.
You enable the user-defined maximum power for the interface with the poe custom maxpwr
active command.
You disable the user-defined maximum power for the interface with the no poe custom
maxpwr active command.
3.5.3.5 poe custom maxpwr active
Description
With this command, you enable use of the user-defined maximum power for the interface.
Requirement
You are in the Interface Configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
poe custom maxpwr active
Result
The user-defined maximum power is enabled for the relevant interface.
Further notes
You configure the user-defined maximum power for an interface with the poe custom
maxpwr command.
You disable the use of the user-defined maximum power with the no poe custom maxpwr
active command.
3.5.3.6 no poe custom maxpwr active
Description
With this command, you disable use of the user-defined maximum power for the interface.
Configuration
3.5 PoE
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
116 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals