12.1 Event and fault handling
In events and faults handling, you set the events whose messages will be distributed in one
of the available ways.
You configure the monitoring of certain system events and power supply and physical
interfaces in the Events configuration mode.
12.1.1 logging console
Description
With this command, you enable the logging of inputs and outputs to the console.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
logging console
Result
The logging function is enabled on the console.
Further notes
You disable the setting with the no logging console command.
As default the function is "disabled".
12.1.2 no logging console
Description
With this command, you disable the logging of inputs and outputs to the console.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
Diagnostics
12.1 Event and fault handling
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
542 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals