Further notes
You disable this function with the no fmp command.
You display the status of this function and other information with the show fmp stauts and
show fmp limit commands.
You define the limit values with the fmp power-loss and fmp rx-power commands.
12.2.2.2 no fmp
Description
With this command, you disable fiber monitoring.
Requirement
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call the command without parameter assignment:
no fmp
Default: enabled
Result
Fiber monitoring is disabled.
Further notes
You enable this function with the fmp command.
You display the status of this function and other information with the and show fmp limit
commands.
You define the limit values with the fmp power-loss and fmp rx-power commands.
12.2.2.3 fmp power-loss
Description
With this command, you specify the limit values for monitoring the power loss per port.
Diagnostics
12.2 FMP