The settings for monitoring the physical network connections have been configured.
Further notes
You can display the current setting with the show events faults config command.
You enable the function with the link command.
12.1.8.12 syslogserver
Description
With this command, you configure the Syslog server address.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli (config-events) #
Syntax
Call up the command with the following parameters:
syslogserver {ipv4 <ucast_addr>} [<port(1-65535)>]
The parameters have the following meaning:
Parameter Description Range of values / note
ipv4 Keyword for an IP address -
ucast_addr Syslog server IPv4 address Enter a valid IPv4 address.
port Serverport 1 .. 65535
Default: 514
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
If you do not select any parameters from the parameter list, the default value is used.
Result
The settings for the Syslog server are configured.
Further notes
You disable the setting with the no syslogserver command.
Diagnostics
12.1 Event and fault handling
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 565

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals