5.2.3.1 ntp server
Description
With this command, you configure the connection to a server on the NTP client.
Note
To avoid time jumps, make sure that there is only one time server in the network.
Requirement
You are in the NTP configuration mode.
The command prompt is as follows:
cli(config-ntp)#
Syntax
Call up the command with the following parameters:
ntp server ipv4 <ip_addr>[port<1025-36564>][poll<seconds(64-1024)>]
The parameter has the following meaning:
Parameter Description Range of values / note
ipv4 Keyword for an IPv4 address -
ip_addr Value for the IPv4 address of the time server Enter a valid IPv4 address
port UDP port of the time server 1025 … 36564
poll Keyword for the time after which the time of day is re‐
quested again
-
seconds Value for the time in seconds 64 … 1024
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
Result
The connection to a server is configured on the NTP client.
Further notes
You delete the connection to a server with the no ntp server command.
System time
5.2 NTP client
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 151

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals