Result
The entry for the start and end of daylight saving time was created.
Further notes
You display the settings for the daylight saving time changeover with the show dst info
command.
5.1.2.4 time dst recurring
Description
With this command, you configure the start and end of daylight saving time with a generic
description.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
time dst recurring <name(16)> begin {<week(1-5)> | last} <weekday>
<month> <hour> end {<week(1-5)> | last} <weekday> <month> <hour>
The parameters have the following meaning:
Parameter Description Range of values / note
name Name of the entry maximum 16 characters
begin Keyword for the start of daylight saving
time.
-
week Calendar week in a month 1 … 5
last Keyword for the last calendar week in a
month
-
weekday Weekday monday, tuesday, wednesday,
thursday, friday, saturday, sunday
month Month january, february, march, april,
may, june, july, august, septem‐
ber, october, november, december
hour Hour 0 ... 23
end Keyword for the end of daylight saving
time.
-
System time
5.1 System time setting
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 147

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals