Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
show loadsave tftp
Result
The current configuration of the TFTP server for Load&Save is displayed.
3.2.3 load tftp
Firmware
The firmware is signed and encrypted. This ensures that only firmware created by Siemens
can be downloaded to the device.
Description
With this command, you load the files from a TFTP server.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call up the command with the following parameters:
load tftp ipv4 <ipv4-address> [port <tcp port (1-65535)>] file
<filename> filetype <filetype>
The parameters have the following meaning:
Parameter Description Range of values / note
ipv4 Keyword for an IPv4 address -
ipv4-address Value for an IPv4 unicast address Enter a valid IPv4 unicast address.
Configuration
3.2 Load and Save
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
92 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals