Parameter Description Range of values / note
link-type Connection status of the following net‐
work segment
point-to-point
shared
Default:
point-to-point
The connection is configured
as full-duplex
shared
in all other cases
portfast Enables the PortFast function -
Default: disabled
port-priority Priority of the interface 0 ... 240 in steps of 16
Default: 128
Note
Configure multiple properties
With each call of the command, you can configure precisely one property.
If you want to configure several properties, call the command several times.
Result
The selected property is configured.
Further notes
You can reset the setting to the default with the no spanning-tree (properties) command.
You display these settings and other information with the commands that start with show
spanning tree ....
6.3.5.2 no spanning-tree
Description
With this command, you reset the various properties of the spanning tree function to the default
value:
The default values are as follows:
Parameter Default value
cost if dynamic calculation of the path costs is not enabled:
200000 for physical interfaces
199999 for port channels
disable The spanning tree function is enabled on the interface
Network structures
6.3 Spanning Tree
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 243

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals