EasyManuals Logo
Home>Siemens>Switch>SCALANCE XR-300WG

Siemens SCALANCE XR-300WG User Manual

Siemens SCALANCE XR-300WG
618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #338 background imageLoading...
Page #338 background image
The parameters have the following meaning:
Parameter Description Range of values / note
GroupName Name of the group max. 32 characters
user Keyword for the user name -
UserName Name of the user max. 32 characters
security-model Specifies which security settings will be
used.
v1
v2c
v3
Storage type Specifies whether the settings remain
following a restart.
volatile :
The settings are lost after a
restart
nonvolatile :
The settings are retained after
a restart.
If optional parameters are not specified when configuring a group, the default values apply.
Result
The details of the group are configured.
Further notes
You delete the details of an SNMP group with the no snmp group command.
You display the created SNMP groups with the show snmp group command.
You display the created SNMP user with the show snmp user command.
7.5.2.11 no snmp group
Description
With this command, you delete the details of an SNMP group.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no snmp group <GroupName> user <UserName> security-model {v1|v2c|v3}
Network protocols
7.5 SNMP
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
338 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals